XD250 OPERATION
Troubleshooting
Error Codes
Problem Cause Action
Unit will not turn on 
(no power)
Yellowwirenotconnectedorincorrectvoltage
Redwirenotconnectedorincorrectvoltage
Checkconnectionsforpropervoltage
(11~16VDC)
Blackwirenotconnected Checkconnectiontoground
Fuseblown Replacefuse
Unit has power 
(but no sound)
Speakerwiresnotconnected Checkconnectionsatspeakers
Oneormorespeakerwirestouchingeach
otherortouchingchassisground
Insulateallbarespeakerwiresfromeach
otherandchassisground
Unit blows fuses
Yelloworredwiretouchingchassisground Checkforpinchedwire
Speakerwirestouchingchassisground Checkforpinchedwire
Incorrectfuserating Usefusewithcorrectrating
Excessive skipping
Unitisnotmountedcorrectly
Checkmountingsleeveoraddabackstrap
support
Physicaldefectinmedia(CD,CD-RorCD-
RW) Checkmediaforscratches
Unit will not accept
a disc
CDmechanismpositionoutofalignment
Press EJECT for 3 seconds to reset
CDmechanismposition
CDtransitscrewsstillinplace
Remove2transitscrewslocatedontopof
theunit.
Error Code Cause Action
ER-1 appears on the display
Disc error
PressejectorRESET
ER-2 appears on the display
Mechanismerrorordiscisupsidedown PressejectorRESET
ER-3 appears on the display
ServoError PressejectorRESET